Navien NPE-2 tankless water heater Error E030

The heater shut down because the flue got too hot (over 149 °F / 65 °C). Navien says clean the inlet filter and flush the heat exchanger.

Clean the cold water inlet filter, then flush the heat exchanger.

Full answer & models

Navien E030 on the NPE-2 means: exhaust overheating. Clean the cold water inlet filter, then flush the heat exchanger.

Applies to: NPE-180A2NPE-210A2NPE-240A2NPE-180S2NPE-210S2NPE-240S2
Also searched as: Navien error E030, Navien E030, Navien error code 030, Navien 030 code

Gas appliance. Power off and let it cool before any maintenance.
Why
If you smell gas: do not try to light any appliance, do not touch any electrical switch, and do not use any phone in your building. Leave and call your gas supplier from a neighbor's phone; if you cannot reach them, call the fire department. Navien: turn the water heater off and disconnect the power supply before maintenance. It can stay hot for several minutes after it is turned off; wait until it cools to avoid burns. Water at or above 125 °F (52 °C) can cause instant scalding, severe burns, or death.

What E030 means

The heater shut down because the flue got too hot (over 149 °F / 65 °C). Navien says clean the inlet filter and flush the heat exchanger.

More detail
Navien's error-code chart (section 5.2) lists E030 as "exhaust overheating". Navien notes the water heater shuts down when the flue temperature exceeds 149 °F (65 °C). If the listed remedies do not resolve the problem, Navien says to contact Technical Support.

5-minute checks

Fix it step by step

Step 1 of 3

  1. Clean the cold water inlet filter

    • 30 min
    • Bucket, Soft brush
    • DIY

    Safety: Gas appliance. Power off and let it cool before any maintenance.

    Drain the heater, then rinse and brush the inlet filter.

    More detail

    Clean the cold water inlet filter.

    Navien sections 4.2 and 4.4: press Power off, close the gas valve, close the cold water supply valve, open hot faucets to drain the lines, put a bucket under the heater and remove the inlet filter (and the recirculation inlet filter and pump drain plug on A2 models). Rinse the filter under cold running water, brush if needed, reinstall and tighten, then refill by reversing the steps.

    Did the code clear?
  2. Flush the heat exchanger (or have it flushed)

    • 1.5 hr
    • Flushing kit (pump, 3 hoses, 5-gal bucket), Service valves
    • Caution

    Safety: Gas appliance. Power off and let it cool before any maintenance.

    Navien calls this a somewhat complicated procedure. If unsure, use a licensed pro.

    More detail

    Flush the heat exchanger (or have it flushed).

    Navien section 4.3: with the heater off and power disconnected, close the hot and cold service valves, connect a circulation pump and hoses to the service valves, and circulate cleaning solution diluted with water through the heater from a 5-gallon bucket for at least 45 minutes, then rinse with fresh water for 5 minutes, clean the inlet filter, and restore power. Navien warns that improper maintenance can void the warranty and says to contact an authorized technician or licensed professional if you are unsure about any step.

    Did the code clear?
  3. Call a licensed pro

    • Decision
    • None
    • Pro decision

    Stop here and book a qualified technician.

    More detail

    Call a licensed pro.

    If E030 returns, have a licensed technician check the venting and heater.

Code cleared. Nice work.

Watch the display for a day to make sure it stays clear.

Back to top

Fixed after any step? Watch the display for a day to make sure it stays clear. Still E030 after step 3? See the replacement part or call a pro.

Call a pro if…

  • E030 returns after cleaning and flushing.
  • Any vent pipe looks damaged, disconnected or blocked.
  • You are not comfortable with the flushing procedure.

Part you'll likely need

Retailer link Some links go to retailers. In the future we may earn a commission from qualifying purchases; it never affects our recommendations.

Only if you are comfortable with the manual's flushing procedure.

Tankless water heater flushing kit (circulation pump, hoses and bucket)

Navien's flushing procedure calls for a circulation pump, three hoses, a 5-gallon bucket and a diluted cleaning solution.

Fits: Heaters with hot and cold service (isolation) valves

Check it on Amazon

FAQ

What does Navien E030 mean?

Exhaust overheating: the heater shuts down when the flue temperature exceeds 149 °F (65 °C), per the NPE-2 chart.