Salt above 4.0 gpl. Dilute to 3.0 to 3.5 gpl.
Salt is above 4,000 ppm. Partially drain and refill with fresh water until it reads 3,000 to 3,500 ppm.
Jandy AquaPure service code 145 means high salinity, above 4.0 gpl. Backwash if you have a DE filter, then partially drain and refill with fresh water until salt returns to 3.0 to 3.5 gpl.
Salt above 4.0 gpl. Dilute to 3.0 to 3.5 gpl.
Verify the high reading before draining.
Confirm salt independently.
Test at the equipment location; temperature affects the readout.
Jandy lists backwashing first if a DE filter is installed.
Backwash a DE filter.
Follow your filter manual's backwash procedure.
Drain part of the water and refill with fresh water until salt is 3.0 to 3.5 gpl.
Partially drain and dilute.
Retest after circulating. Repeat in stages as needed.
As an Amazon Associate I earn from qualifying purchases. CodeFix earns a commission if you buy through these links, at no extra cost to you.
An independent salt reading is the first check.
Retesting between drain-and-refill stages tells you when to stop.
Above 4.0 gpl (4,000 ppm), per Jandy H0325600.
The manual says above 4.0 gpl may damage the power center and above 6.0 gpl may corrode pool fixtures.
Jandy AquaPure/PureLink Power Center and Cell Kit, Installation and Operation Manual (H0325600), Section 7.2 Service Codes, Section 4.7 Salt, Section 6.3 Electrolytic Cell Cleaning.
Source: Jandy AquaPure/PureLink Power Center and Cell Kit, Installation and Operation Manual (H0325600), Section 7.2 Service Codes, Section 4.7 Salt, Section 6.3 Electrolytic Cell Cleaning. Written by a Florida pool service owner. Updated 2026-10-15.