Pentair MasterTemp gas pool heater Error E05 / E06

Stack flue sensor open or shorted. E05 means the stack flue sensor circuit is open; E06 means it is shorted.

Turn the heater off and have a qualified service technician check it, as Pentair's manual directs for E05 / E06.

Full answer & models

Pentair MasterTemp E05 / E06 means stack flue sensor open or shorted. Turn the heater off and call a qualified technician.

Applies to: MasterTemp 175K (460792, 460793)MasterTemp 200K (460730, 460731, 461000, 461001, 461032)MasterTemp 250K (460732, 460733, 460771, 460772, 460806, 461020)MasterTemp 300K (460734, 460735)MasterTemp 400K (460736, 460737, 460775, 460776, 460805, 461021)
Also searched as: Pentair E06, MasterTemp E05, MasterTemp E06, Pentair heater E05 error

Gas appliance. Do not keep operating the heater with this code; shut it down and call a technician.
Why
Pentair, what to do if you smell gas: do not try to light any appliance; do not touch any electrical switch and do not use any phone in your building; immediately call your gas supplier from a neighbor's phone. Pentair: this product must be installed and serviced by authorized personnel qualified in pool/spa heater installation; improper installation or operation can create carbon monoxide and flue gases that can cause serious injury or death. Pentair warning: risk of explosion or fire causing burns or death if safety interlocks are disabled. Do not operate the heater when ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, E06 or 126 is displayed; shut down the heater ("To turn off gas to appliance", page 43) and have a qualified service technician check the system.

What E05 means

Stack flue sensor open or shorted. E05 means the stack flue sensor circuit is open; E06 means it is shorted.

More detail
Pentair's MasterTemp Installation and User's Guide (Table 8, Heater Error and Fault Codes, page 48) lists E05 / E06 as "Open stack flue sensor (E05) / shorted stack flue sensor (E06)". E05 means the stack flue sensor circuit is open; E06 means it is shorted. Pentair: for E06 the front panel buttons are disabled; to reset the heater, cycle power.

5-minute checks

Fix it step by step

Step 1 of 2

  1. Shut the heater down

    • 2 min
    • None
    • DIY

    Safety: Gas appliance. Do not keep operating the heater with this code; shut it down and call a technician.

    Pentair: do not keep running the heater with this code.

    More detail

    Shut the heater down.

    Pentair's "To turn off gas to appliance" (page 43): press the OFF button on the operating control and switch off all electric power to the unit. Pentair's remaining steps (removing the access panels to close the gas valve) can be left to your technician.

    Did the code clear?
  2. Call a qualified service company

    • Decision
    • None
    • Pro decision

    Stop here and book a qualified technician.

    More detail

    Call a qualified service company.

    Pentair's manual says only qualified, trained service technicians with appropriate test equipment should service the heater. Pentair lists E05 and E06 among the codes where you should not operate the heater and should have a qualified service technician check the system (troubleshooting diagram, page 54).

    Still showing E05?Need a pro → call a pro

Code cleared. Nice work.

Watch the display for a day to make sure it stays clear.

Back to top

Fixed after any step? Watch the display for a day to make sure it stays clear. Still E05 after step 2? call a pro.

Call a pro if…

  • You smell gas (leave first, then call your gas supplier from a neighbor's phone).
  • E05 / E06 is displayed and does not clear, or keeps returning.
  • Anything inside the heater cabinet, wiring, or the gas valve.

FAQ

What does E05 / E06 mean on a Pentair MasterTemp?

"Open stack flue sensor (E05) / shorted stack flue sensor (E06)", per Table 8 of the MasterTemp manual. E05 means the stack flue sensor circuit is open; E06 means it is shorted.

Source: Pentair MasterTemp Pool and Spa Heater Installation and User's Guide, Table 8 Heater Error and Fault Codes and Troubleshooting, pp. 45, 48 and 54. Written by the DIY Error Codes team. Updated 2026-10-16. DIY Error Codes is independent and not affiliated with or endorsed by Pentair.