Pentair MasterTemp gas pool heater Error ERR PS
Not enough water flow (pressure switch). Pentair says ERR PS indicates insufficient water flow to the heater.
Make sure the pump is running and clean the filter and skimmers. If ERR PS stays on, call a qualified technician.
- Gas appliance
- Owner check, then pro
Full answer & models
Pentair MasterTemp ERR PS means not enough water flow (pressure switch). Check the pump, filter and skimmers; if it stays, call a technician.
Why
What PS means
Not enough water flow (pressure switch). Pentair says ERR PS indicates insufficient water flow to the heater.
More detail
5-minute checks
Fix it step by step
Make sure the pump is running
- 2 min
- None
- DIY
Safety: Gas appliance. Service only by a qualified technician.
The pressure switch senses that the pump is running.
More detail
Make sure the pump is running.
Pentair: the pressure switch (PS) senses that the pump is running. With no water flow the heater shows ERR PS.
Did the code clear?Clean the filter and skimmers
- 20 min
- None
- DIY
Pentair's owner-level fix for ERR PS.
More detail
Clean the filter and skimmers.
Pentair (page 45): if the pump is operating, ERR PS usually indicates that the filter and/or skimmers should be cleaned (some filters may require back-washing). The error clears once water flow is established.
Did the code clear?Call a qualified service company
- Decision
- None
- Pro decision
Stop here and book a qualified technician.
More detail
Call a qualified service company.
Pentair's manual says only qualified, trained service technicians with appropriate test equipment should service the heater. Pentair: if the message remains on after the filter and skimmers have been serviced, the system should be checked by a qualified service technician.
Still showing PS?Need a pro → call a pro
Call a pro if…
- You smell gas (leave first, then call your gas supplier from a neighbor's phone).
- ERR PS is displayed and does not clear, or keeps returning.
- Anything inside the heater cabinet, wiring, or the gas valve.
FAQ
What does ERR PS mean on a Pentair MasterTemp?
"Water pressure switch open", per Table 8 of the MasterTemp manual. Pentair says ERR PS indicates insufficient water flow to the heater.
Will ERR PS clear by itself?
Yes. Per Table 8, if water flow is established the error is cleared and normal operation resumes.
Source: Pentair MasterTemp Pool and Spa Heater Installation and User's Guide, Table 8 Heater Error and Fault Codes and Troubleshooting, pp. 45, 48 and 53. Written by the DIY Error Codes team. Updated 2026-10-16. DIY Error Codes is independent and not affiliated with or endorsed by Pentair.